The ALIAMAG AMC3200E Series is a heat meter converter of electromagnetic flowmeter that can be paired with any of ALIA AMF series sensors. The unit features multiple display parameters including flow rate, energy, flow total, energy total, supply temperature, return temperature, diagnostic, programming and troubleshooting. It’s equipped with MODBUS, Bluetooth and BACnet protocol.
Fitur
- Four line LCD display Flow Rate / Energy / Totalizer / Temperature
- +/-0.2% value of reading
- Bi-direction flow measurement, and the display can rotate
- With hourly report, daily report, monthly report and yearly report
- query function
- 99 times / dates records for alarm
- 99 (total) times records for power on / off
- MODBUS, Bluetooth, BACnet protocol
Spesifikasi
Excitation | : | DC Plused |
Display | : | 4 Lines LCD with backlight |
Line 1 | : | Date and Time |
Line 2 | : | 5 Digit flowrate |
6 Digit energy value | ||
Error code | ||
Supply temperature | ||
Line 3 | : | 9 Digit totalizer for forward flow / reverse flow |
9 Digit totalizer for heat / cold energy | ||
Error code content | ||
Return temperature | ||
Line 4 | : | Differential temperature |
Unit | : | L/s, L/min, L/hr, m3/s, m3/min, m3/hr, |
mL/hr, mL/min, mL/s, kW, MW, KJ/hr, | ||
MJ/hr, GJ/hr, Mcal/hr, Kcal/hr, Cal/hr, BTU/hr | ||
Measuring Range | : | Min. 0-0.15 m/s |
: | Max. 0-15 m/s | |
Accuracy | : | +/-0.2% of reading (Velocity≥0.5 m/s) |
: | +/-0.001 m/s (Velocity<0.5 m/s) | |
Repeatability | : | +/-0.05% of reading |
Current Output | : | 4-20 mA (Isolated) |
Load | : | Max. 600 Ω |
Pulse Output | : | Open collector |
Rating | : | 3-30 VDC, 50 mA Max. |
Pulse Rate | : | 1) Scaled pulse, (L/Pulse, Other) |
: | 2) Frequency: 0-5000 Hz | |
Communication | : | Bluetooth (Apply to Android System) |
RS485 (MODBUS Protocol) / BACnet |
Keypad | : | 3 External keys for programming |
and display control | ||
Low Flow Cutoff | : | 0-9.9% |
Data Logger Function | : | 99 Date / time records for alarm |
Record Data | : | Date / time of power on/ off |
: | 99 Years flow rate / energy / | |
temperature / total flow / total energy | ||
Record data every one hour | ||
Damping | : | 0.1-99.9 s |
Self Diagnosis | : | The following error messages are |
displayed if failure occurs | ||
– Temperature failure | ||
– Temperature abnormal | ||
– Empty pipe | ||
– EEPROM abnormal | ||
Data Storage | : | Operation parameters and totalizer |
figures are stored by EEPROM for more | ||
than 10 years | ||
Cable Entry | : | Standard: M20Â Option: 1/2″ NPTF |
Protection Class | : | IP67 |
Ambient Temperature | : | -25-65 °C |
Material | : | Aluminum Alloy |
Temperature Input | : | PT1000, 2 wires |
Power Supply | : | 90-260 VAC, 50/60 Hz |
: | 24 VDC +/-10% (Option) | |
Power Consumption | : | 10-20 W (Dependent on sensor size) |
Weight | : | 4.5 kg |
Mounting | : | Bracket on 2″ pipe |
Reviews